Alcohol in the industrial work environment is a dangerous mix. Occupational Health and Safety regulations must account for a zero-tolerance policy on the consumption of alcohol at work. The use of Breath Testing equipment will lead to a deterioration in alcohol related absences and accidents in the workplace.
Alcohol can be measured in the blood up to 12 hours after drinking this will ensure you are able to check whether employees are working at their physical peak.
Legal requirements call for staff to be successfully monitored in order to track a historical record of infringements on company policy. A strong policy is only as good as the equipment used to uphold it. That’s why Alcolizer Australian certified products are the choice in industrial health and safety applications.
Our most accurate basic test unit
* Digital Readout - The digital readout indicates to the operator a 3 decimal place result, providing high accuracy.
* Re-calibration Indicator.
* Back lit display.
* The world's best Micro Fuel Cell Technology Cell Technology.
* Standard 12 month warranty
* Digital Readout - The digital readout indicates to the operator a 3 decimal place result, providing high accuracy.
* Re-calibration Indicator.
* Back lit display
* The world's best Micro Fuel Cell Technology Cell Technology.
* Data logger with 1000+ storage
* Standard 12 month warranty
* CUSTOM S'Print supplied together with adapter connections
* Download cable and Software provided data storage 2000+ tests
* HH2 – available as stand-alone unit
After more than two years research and development, the Alcolizer LE is now available. Utilizing "state of the art" technology the LE incorporates many features never before offered in alcohol breath test equipment. The development of the Alcolizer LE has resulted in NSW Police (one of the largest in the world) thoroughly testing and then selecting the LE to replace all its hand held alcohol breath test devices. This "state of the art" product is now available.
Features:
1. Highly responsive, mini electrochemical fuel cell
2. Very fast zero test recovery
3. Color graphics LCD display
4. Easy "mobile phone style" menu operation
5. Multi-function capability - active, passive and "evidential test" modes
6. RF shielded aluminum case
7. Rechargeable battery system or Alkaline batteries up to 3,000 tests
8. 20,000 + data logging, USB download connection
9. Accuracy better than +/- 5%
10. Different levels of security coded, programmable settings
11. Programmable statistic gathering options
12. Lightweight (400gms), ergonomic design
13. Leather case with reflective strips and hand strap (customized option available)
Options:
1. GPS with built in antenna
2. RF download (auto or manual) to base computer
3. Tailored software packages
Our flagship product the Alcolizer Wall Mounted unit is a unique industrial standard Alcohol Breath Analyser. This unit is designed to be robust and hard-wearing. Virtually tamper proof and requiring minimum user intervention to give the most accurate results.
The automatic calibration Alcolizer WMs means that this is the most economical method of measuring alcohol levels in staff. For as little as R5.00 (ZAR) per day you have unlimited tests and unprecedented accuracy. As the first Australian Standards Certified wall mount unit, the auto calibration Alcolizer offers unrivalled accuracy and reliability, calibrating itself from its own internal certified gas every 24 hours.
With evidential style test and internal printer options, no other wall mount breath tester can compete with the performance and features of the Alcolizer WMs. The unit can be integrated into an existing Access control system or become the central point in a new system. Integration has already taken place at many locations around South Africa.
Features:
1. Australian Standards Certified - As Type III
2. Automatic calibration models
3. Electrochemical fuel cell technology (EC fuel cell technology is used in Police devices around the world)
4. Factory programmable scrolling LED display
5. Proven robust, shell case for all weather operation
6. Low cost maintenance and consumables (standard drinking Straws)
7. Access control integration
8. 12 month Warranty
9. Actual dimensions 40.0 x 51.0 x 15.5cm
Options:
1. Data logging
2. Internal printer ![]()
3. "Evidential style" test model available
The installation of an Alcolizer offers staff a self-test system enabling them to test themselves before entry to the plant should they feel they are at risk. A positive voluntary test would not normally attract punitive measures from the employer, other than the possible deduction of the associated waiting time until the worker is able to give a ‘zero’test. If, however, a worker is caught inside the plant with a positive reading, having not availed himself of the entry test, then clearly he would be in deep trouble.
The underlying principle in this system is that the workforce becomes self-regulatory because the staff understands the safety risks associated with the effects of alcohol, as well as the unpleasantness of possible anti-social behaviour that often goes hand in hand with alcohol consumption.
1. Fast and easy testing operation – quick detection and quick recovery time.
2. Two modes of operation – active by blowing and passive by sucking.
3. Testing results announced by voice.
4. No mouthpieces required.
5. No regular calibration adjustments needed (annual calibration recommended)
6. Low power. Saving mode activates in 3 minutes automatically.
7. Complete system includes – AlcoLight tester, mains charger, 12V DC car charger, black pvc carry case.
8. Results from this AlcoLight tester are for reference purposes only.
9. Exclusively supplied and serviced by Runrite Electronics
10. Full after-sales support provided - Guaranteed
Alcohol Light:
There are three lights to indicate the alcohol concentration after a test is completed:
Green |
with 1 buzz / voice |
No alcohol (<0.5 0/00) |
Amber |
with 3 buzzes / voice |
Low concentration (0.5 ~ 0.8 0/00) |
Red |
with 5 buzzes / voice |
High concentration (>0.8 0/00) |
General driving limit in South Africa is 0.5%BAC. The AlcoLight is ideal for use at security check points, in pubs, bars and restaurants.
HH2 with Vehicle operation unit uses RF frequency to control the ignition switch of the vehicle. In other words if the breath test is a fail the vehicle will not start.
This is ideal for use in fleet management systems and has found great success in curbing bus and taxi accidents in countries like China and Australia.